Skip to content
MaritimeTest

TOTS 1B-Engine Room Operations – Manoeuvring

CBT 37 questions

First 5 of 37 questions — with answers

The correct answer is marked. Unlock the rest to study the whole test, online or offline.

  1. Question 1

    As per SOLAS requirements, where should the quick close fuel valves’ release cabinets be located?
    • Outside the engine room.
    • Inside the engine room.
    • Near the engine control room.
    • On the navigation bridge.
  2. Question 2

    Does SOLAS legislation exist stating how many steering gear hydraulic pump units are directly connected to the emergency switchboard?
    • According to SOLAS legislation all the pumps should be connected.
    • No such requirement exists.
    • Yes, according to SOLAS legislation there should be a minimum of one pump.
    • SOLAS do not have the power to legislate on this requirement.
  3. Question 3

    During manoeuvring what condition would you expect to consistently apply to the starting air system?
    • At least two air compressors should be running at all times.
    • Only one air compressor should be run at all times and the second one kept on stand-by.
    • The starting air pressure should be kept at the maximum possible level at all times.
    • The bridge should be informed of the status of the starting air capacity on a regular basis.
  4. Question 4

    How many generators would you expect to have running during manoeuvring?
    • Sufficient to allow for continuous supply should one alternator trip.
    • All available generators.
    • One running and one on standby.
    • Sufficient for 100 % normal seagoing load.
  5. Question 5

    If one unit of the main engine is out of order due to a fracture in the liner, what action should be taken with respect to the scavenge air supply to the unit before manoeuvring?
    • No action needs to be taken with respect to the scavenge air.
    • The exhaust valve should be adjusted to remain open during the full cycle to prevent build up of air pressure.
    • The scavenge air should be isolated from the unit.
    • The scavenge air should be increased to improve cylinder cooling.

Preview — 5 of 37 questions

You are seeing the first 5 questions with answers. Unlock the remaining 32 to study the whole test — online or offline.

About this CBT test

TOTS 1B-Engine Room Operations – Manoeuvring is a CBT test with 37 questions and verified answers. Common topics include: main engine, out, action, room, alarm, oil, expect, defective.

You can practise the free questions online — one at a time, with the correct answer — or unlock the whole test and download it to study offline, without internet.

Related CBT tests