Introduction to Inert Gas Systems

Mintra 5 questions

Study guide

Download PDF

An inert gas system keeps cargo tank atmospheres too oxygen-poor to support combustion. This guide covers the main components, when the system is used, what to do if it fails, and why it matters even with an empty tank.[1]

Main components

A typical inert gas system includes a scrubber tower, a pressure/vacuum breaker and a demister, together with the associated blowers, deck water seal and piping.

When the system is used

The inert gas system is used during tank cleaning, cargo loading and cargo discharge — that is, whenever the tank atmosphere is being disturbed and could otherwise enter the flammable range.

If the system fails

If the inert gas system fails, the crew must take action to prevent any air ingress to the tanks, close the deck isolating valve, and stop any cargo or ballast operations from inerted tanks. These steps keep oxygen out until inerting can be restored.

Why it matters

Even with no cargo on board, flammable vapours may still be present within a vessel's storage tanks, which is why tank atmospheres are kept inert. The relationship between the composition and flammability of a specific hydrocarbon gas, air and inert gas in cargo tanks is often displayed in a flammability diagram.

Key facts to remember

  • Components: scrubber tower, pressure/vacuum breaker, demister.
  • Used during tank cleaning, cargo loading and cargo discharge.
  • On failure: prevent air ingress, close the deck isolating valve, stop cargo/ballast operations from inerted tanks.
  • Flammable vapours can remain in tanks even with no cargo on board.
  • Hydrocarbon/air/inert-gas flammability is shown on a flammability diagram.

Sources

  1. SOLAS Chapter II-2 and the International Code for Fire Safety Systems (FSS Code) — inert gas systems for tankers; with reference to industry tanker guidance (ISGOTT).

Compiled from the sources above and cross-checked against the official documents. Published by the MaritimeTest editorial team.

First 4 of 5 questions — with answers

The correct answer is marked. Unlock the rest to study the whole test, online or offline.

  1. Question 1

    A typical inert gas system includes which of the following components?
    • A scrubber tower.
    • A pressure vacuum breaker.
    • A fuel injector.
    • A demister.
  2. Question 2

    If the inert gas system fails, what should the crew do?
    • Open all hatches and vents.
    • Take action to prevent any air ingress to the tanks.
    • Purge the tanks.
    • Close the deck isolating valve.
    • Open the pressure regulating valve.
    • Stop any cargo or ballast operations from inerted tanks.
  3. Question 3

    Even with no cargo onboard, flammable vapours may still be present within a vessel's storage tanks.
    • True.
    • False.
  4. Question 4

    The inert gas system will be used during which of the following operations?
    • Tank cleaning.
    • Cargo loading.
    • Cargo discharge.
    • Bottom painting.