Download PDFA fixed carbon dioxide (CO₂) system floods a space with CO₂ to smother a fire by removing the oxygen. It is powerful and permanent, and lethal to anyone still inside. This guide covers inspection, coverage, the hazards and re-entry.[1]
The CO₂ firefighting system should be inspected monthly. Fixed CO₂ systems typically protect cargo holds, engine rooms and pump rooms.
Carbon dioxide is lethal to people, not just to fire. CO₂ levels higher than 17% can result in loss of bodily control, unconsciousness, convulsions, coma and death.
When the system's control cabinet is opened, a sequence of safety actions occurs: the fire flaps will close, the space's ventilation will be deactivated, and the carbon dioxide alarm will activate. Treat the alarm as an order to evacuate — the space is about to be flooded.
Before re-entry, a CO₂-filled space must be left for at least 24 hours as a minimum, to allow the atmosphere to be made safe.